How Close Can A Tankless Water Heater Be To An Electrical Panel?

There must be clear working space at least 36″ out from the panel. The width of the working space must be a minimum of 30″, or as wide as the equipment if wider.

How far does a tankless water heater need to be from electrical panel?

The only code requirements I’ve found regarding clearances around an electrical panel are allowing at least a 30″ working space (side to side).

How close can an electrical panel be to a water heater?

Basically, the panel can be anywhere in the 30″ width working space. There is no mention of center of the panel or otherwise. Meaning, the panel can be at the extreme side of the 30″ space as long as the space is clear for 30″.

How far does an electric panel need to be from a water source?

3 of the IRC specifies that a a dedicated space must exist around the panel and must be kept free of pipes, ducts and any equipment not pertinent to the electrical installation. This space extends from the floor to the ceiling or to a point 6 feet above the top of the panel, whichever is lower.

How much clearance does a tankless water heater need?

A tankless water heater requires a 4-foot clearance from the side or below a door or window that opens, unless the unit is directly vented to the outside. If the water heater is installed above the door or window, it needs 12 inches of clearance.

How close can a tankless water heater be to a gas meter?

36”
Tankless Water Heaters
Note: PG&E requires a minimum horizontal clearance of 36” between the gas meter and a tankless water heater when located on the same wall.

See also  Which One Is Better Alexa Or Google Home?

How much clearance is needed around an electrical panel?

The Occupational Safety and Health Administration (OSHA) and the National Electrical Code (NEC), require that electrical panels have a minimum of 3 feet (36 inches) of clearance and a minimum headroom of 6.5 feet or the height of the equipment whichever is greater.

How close can water panels be?

The 30″ clearance side to side is correct for panels 30″ or smaller… after that the clearance has to be at least equal to the width of the panel…but in the case of a panel that is smaller than 30″… the clearance can all be to one side or the other of the panel… so the water main can be 1″ away on the right with a 16″

How close can a junction box be to a water line?

There is no required spacing for a water pipe and a junction box if a plastic box it could be in contact with your copper. A metal box you would want an air gap as any moisture in the air (humidity) and a copper / galvanized contact the pipe will spring a leak over time because of galvanic corrosion.

How close can a sink be to a electrical panel?

There is no rule preventing a panel from being next to a sink. 3′ in front and 30 inches wide are all you need to give the clearances.

Can tankless water heater go in a closet?

Your tankless water heater can be installed just about anywhere! Due to the small size of your water heater, it can be mounted in many small spaces, including closets, under sinks, in pantries, or under stair storage areas.

See also  Why Does Washing Machine Fill With Water When Switched Off?

Where should a tankless water heater be installed?

The ideal location for your water heater is inside the home. Most installations are small and unobtrusive so they will easily fit in a pantry, under the stairs, or under your sink. If you must place the water heater outside, make sure it’s safe from direct sunlight, rain, and insects.

Does a tankless water heater need a dedicated gas line?

Tankless water heaters provide hot water on-demand. Gas units require a gas line, adequate combustion air, a vent to remove combustion gas and an electrical outlet to power the unit. While they last longer than tank-style water heaters, they are more costly to install and often require upgrading your gas line.

Can a gas tankless water heater be installed in a bathroom?

Tankless water heaters can be installed anywhere inside your home. You can even have a tankless water heater in a bathroom! Some families with larger homes choose to install two, one for each floor, for example. Because of their small size, they fit in closets, cabinets, pantries or laundry rooms.

Can a gas water heater be installed in a closet?

Yes, a gas water heater can be installed in a closet as long as the closet is not used for storage. The International Residential Code (IRC) specifically bans a storage closet as a location for a gas water heater.

Can I build a closet around my electrical panel?

ANSWER: According to Section 240-24(d) of the National Electrical Code (NEC), which says “Overcurrent devices shall not be located in the vicinity of easily ignitable material, such as in clothes closets,” you are not permitted to do this.

Can water lines run above electrical panel?

Items such as HVAC ducts, gas pipes, water pipes and drain pipes are foreign to the electrical system and, therefore, shall not be installed within the dedicated equipment space.A copper plumbing pipe has been installed above the panelboard and above the 6-foot dedicated equipment space.

See also  What Light Bulb Should I Use Outside?

How close can water and electric lines be?

12 inches
24 inches between gas and electric lines. 12 inches between water and electric lines. 24 inches between sewer and electric lines. 12 inches between communications and electric lines.

Can plumbing and electrical be in the same wall?

You can definitely run wires close to plumbing wires, provided you aren’t running a bare or damaged copper wire next to steel pipes. According to the code, you can run plumbing and electrical wires through the same hole, but you need to make sure the wire is well insulated and there is no risk of ruptures.

Can electrical wires touch ductwork?

As long as there are no sharp edges in the chase that might physically damage the cable, there’s no code violation if Romex touches metal hvac supply or return ducts.On the other hand, it’s common practice to run Romex perpendicularly across a panned stud cavity or joist bay used as a cold air return duct.

Can an electrical panel be above a countertop?

You cannot put it over anything. You cannot put it next to anything. There must a clear space in front of the panel for an electrician to stand.In your case, locating the panel under a counter would require an electrician to work on his or her knees when working in the panel.