Dielectric Unions If either the tank nipples or the pipes are galvanized steel, however, and you are connecting them to copper, you must use a fitting called a dielectric union to make the connection.Both the hot and cold water pipes must have this fitting — it’s a code requirement.
Can you use dielectric union on water heater?
You need to use dielectric unions to connect an electric water heater to a system of copper pipes if the heater came with preinstalled galvanized nipples.
Why are dielectric unions used on water heaters?
Dielectric unions are used to join pipes made from different metals to prevent accelerated corrosion in the piping system. This fitting is utilized to transition between steel and copper piping with a maximum operating pressure of 250 psi and 180-degrees Fahrenheit.
Do Rheem water heaters need dielectric unions?
Re: Rheem says: dielectric not necessary! Interesting. They must mean that a dielectric union is not required to prevent problems with the water heater. However, no dielectric union between dissimilar metal connections will likely result in failure of the piping at that point.
Where are dielectric unions required?
In most jurisdictions plumbing codes require the use of a dielectric fitting when joining steel piping to copper or other metals; some plumbing jurisdictions permit use of a 6-inch brass nipple in this location as an alternative to diaelectric fittings.
When should a dielectric union be used?
Dielectric Unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metal.
Why do dielectric unions fail?
every single union fails miserably by either leaking, clogging up completely, rusting to pieces with no water contact outside pipe or depositing rust in water.
Is it OK to use galvanized pipe for water heater?
Thanks. Black steel is the prefered pipe material, followed by copper. Galvanized should not be used. Galvanized Pipes in a Hot Water Heating System.
Are SharkBite fittings dielectric?
The standard SharkBite fittings (i.e. Coupling, Elbow, Tee) cannot be used as a dielectric union. However, SharkBite Stainless Steel Braided Flexible Coupling Hoses can be used as a dielectric union.
Do Rheem water heaters have heat traps?
Today, most tank-type water heaters such as Rheem, AO Smith, State, American, Bradford White, and others are equipped with two heat traps (hot and cold pipes) to increase energy efficiency, while those without can be retrofitted. The most used types are with the metal nipples with the flaps or balls inside.
Are water heater nipples dielectric?
The 5″ dielectric nipple is designed for use in water heater inlet and outlet hook-ups and for other uses where dissimilar metals occur in piping and plumbing systems. The thermoplastic lining helps prevent corrosion and the ends are 3/4″ NPT tapered pipe thread for a fluid-tight seal.
Does stainless steel need dielectric union?
The contractor did not think copper and stainless steel were dissimilar metals, and that stainless steel and copper are corrosion-resistant materials, and so a dielectric union or dielectric waterway was not required.In this case, the change was from copper or galvanized water mains to stainless steel mains.
Do you need dielectric union for copper to brass?
Brass is a copper/zinc alloy, so a brass nipple qualifies as a type of copper alloy fitting that is cited as acceptable by the code. While a dielectric union (shown above) provides a break in electrical conductivity that theoretically would be best, most plumbers prefer a brass fitting.
Will brass work as a dielectric union?
Brass is the best alternative for a dielectric union for water distribution system problems. It is used where water is not of great quality as it is the area where mostly corrosion takes place as dielectric will not work with the corrosion. It is made up of an alloy of copper and zinc.
Does brass cause electrolysis?
Metals that are different, such as galvanised, steel, brass and copper pipes come into contact with each other can cause electrolysis.
Does brass prevent electrolysis?
Dielectric unions are commonly used around commercial and residential water distribution systems to avoid electrolysis and deterioration in the piping systems.Threaded brass is widely used for fittings for copper pipe and brass connectors of any kinds are used in the repair industry.
Do dielectric unions leak?
A dielectric union is a plumbing fitting that is meant to join two dissimilar metal pipes so they don’t experience a galvanic reaction and begin to rust.We find many dielectric unions that have started to rust which will eventually lead to a water leak if not remedied.
Can you use PEX on hot water heater?
Can I Connect PEX to My Water Heater? PEX can’t be directly connected to a water heater.from your water heater and connect the PEX to the pipe.
Why do you need dielectric unions?
Dielectric unions are used to separate two dissimilar metal pipes (such as copper pipes and galvanized steel). Purpose of dielectric unions is to prevent galvanic corrosion, which is caused by electrolysis.
What is the difference between black iron pipe and galvanized pipe?
What is the main difference between black steel pipe and galvanized steel pipe? Black steel pipe and galvanized pipe are made of steel, but galvanized pipe has a zinc coating while black pipe does not and therefore, galvanized pipe is more expensive and more durable.
What is a dielectric union?
Dielectric Unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metal. We offer dielectric unions in a range of configurations, sizes, and materials.